Server Technology Solutions for the Data Center Equipment Cabinet Sentry Commander - PT40 Installation and Operations Manual © 2004-2005 Server
Interfaces The Commander has two interfaces: the HTML interface accessed via the HTTP enabled Ethernet connections and the command line for serial and
HTML Interface The HTML interface is constructed of three major components: the System Location bar, the User/Navigation bar and the Control Screen.
Outlet Control The Outlet Control section offers access to the Individual and Group outlet control pages. From the Individual and Group pages, the us
Configuration The Configuration section offers access to all unit configuration options including Network, Telnet/SSH, HTTP/SSL, Serial Ports, Users,
Telnet/SSH The Telnet/SSH configuration page used to enable or disable Telnet and SSH support and configure the port number that the Telnet or SSH ser
Serial Ports The Serial Ports configuration page is used for maintenance of all serial/Pass-Thru ports. NOTE: Pass-Thru connections may only be initi
Outlets The Outlets configuration page is used for assignment and/or editing of outlet sequence and reboot timers, descriptive names and wakeup states
Changing a user password: Click on the Edit link in the Action column for the associated user. On the subsequent User Edit page, enter a password and
Setting the filepath: Enter the path of the file to be uploaded in the Directory field, and press Apply. Setting the filename for upload: Enter the fi
Setting the LDAP server IP address: Enter the IP address in the Host IP1 and/or Host IP2 address field and press Apply. Changing the LDAP server port:
Instructions This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literatu
Granting or removing Environmental Monitoring viewing privileges: Click on the Edit link in the Action column for the associated LDAP Group. On the su
Adding and Deleting outlet access: Click on the Outlets link in the Access column for the associated TACACS+ Privilege Level. On the subsequent LDAP
Command Line Interface Logging In Logging in through Telnet requires directing the Telnet client to the configured IP address of the unit. Logging in
Administrative Command Summary (continued) List User Displays all accessible outlets/groups/ports for a user List Users Displays privilege levels fo
Operations Commands Operations commands manage outlet states, provide information about the Sentry environment and control session operations. Turning
Displaying outlet status The Status command displays the on/off status of one or more outlets. The command displays the status of only those outlets
Displaying accessible outlets The List Outlets command displays accessible outlets for the current user. The display includes the absolute and descri
Displaying infeed status The Istat or Iload command displays the status of one or more infeed. This display includes the infeed absolute and descript
Administration Commands Administration commands may only be issued by a user with administrative privileges, such as the predefined Admn user or anoth
Setting user access level privileges The Set User Access command sets the access level privileges for a user. The Sentry has four defined access pr
Table of Contents CHAPTER 1: INTRODUCTION 4 Quick Start Guide...
Adding outlet access to a user The Add OutletToUser command grants a user access to one or all outlets. To grant access for more than one outlet, bu
Deleting serial/Pass-Thru port access for a user The Delete PortFromUser command removes a user’s access to a serial/Pass-Thru port. You cannot remove
Creating a descriptive outlet name The Set Outlet Name command assigns a descriptive name to an outlet. You may use this name in commands that requir
Displaying outlet information The Show Outlets command displays information about all outlets. This information includes: • Sequencing and reboot t
Adding an outlet to a group The Add OutletToGroup command adds an outlet to a group. To add more than one outlet, but not all outlets, you must use m
Enabling or disabling active signal checking for serial/Pass-Thru connections The Set Port Dsrchk command enables or disables active signal checking f
Displaying serial/Pass-Thru port information The Show Ports command displays information about all serial/Pass-Thru ports. This information includes:
Setting the LED display orientation The Set Display command is used to configure the Current LED(s) display orientation. To set the LED display orient
Creating a descriptive infeed name The Set Infeed Name command assigns a descriptive name to an infeed. This descriptive name is displayed when the S
Setting the subnet mask The Set Subnet command sets the subnet mask for the network the PT40 will be attached to. To set the subnet mask: At the Sentr
Chapter 1: Introduction Quick Start Guide The following instructions will help you quickly install and configure your Commander for use in your data
HTTP Administration NOTE: A restart is required after setting or changing ANY Telnet/Web configurations. See Performing a warm boot on page 38 for m
FTP Administration You may upload new versions of firmware into the Sentry using File Transfer Protocol (FTP). This allows access to new firmware rel
Displaying FTP configuration information The Show FTP command displays all FTP configuration information. • FTP Host IP address • FTP Host username
Chapter 4: Advanced Operations SSL 44 Enabling and Setting up SSL Support 44 SSL Technical Specifications 44 SSH 45 Enabling and Setting up SSH Supp
SSL Secure Socket Layers (SSL) version 3 enables secure HTML sessions between a Sentry Remote Power Manager and a remote user. SSL provides two chief
SSH Secure Shell (SSH) version 2 enables secure network terminal sessions between a Sentry Remote Power Manager and a remote user over insecure networ
SNMP The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP request
Setting the trap timer The Set Traptime command sets the timer period between repeated error-condition traps. The valid range for the timer period is
SNMP Traps The Sentry supports three types of SNMP traps. Traps are enabled at the tower (T), infeed (I) or outlet (O) level. Trap Summary Name Level
Load Trap The Load trap is generated whenever the total input load on an infeed exceeds a preset threshold. Load traps include the reported input loa
Equipment Overview 1. The power inlet/cord(s) connects the Commander to the electrical power source. 2. One RJ12 Aux connector for connection to an
Enabling or Disabling a Load trap The Set Trap Infeed Load command is used to enable or disable an Infeed Load trap. To Enable or Disable a Load trap:
Displaying trap configuration information The Show Traps command displays information about all traps. To display trap information: At the Sentry: p
LDAP The Sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3. This support enables authentication with LDAP se
Enabling and Setting up LDAP Support There are a few configuration requirements for properly enabling and setting up LDAP support. Below is an overvi
Setting the search bind Distinguished Name (DN) The Set LDAP BindDN command is used to set the fully-qualified distinguished name (FQDN) for user acco
Setting the user search base Distinguished Name (DN) The Set LDAP UserBaseDN command is used to set the base (DN) for the login username search. This
Displaying LDAP configuration information The Show LDAP command displays LDAP configuration information. • Enabled-disabled status of LDAP support •
Configuring LDAP Groups Creating an LDAP group The Create LDAPGroup command creates an LDAP group. To create an LDAP group: At the Sentry: prompt, typ
Displaying the LDAP access privilege levels The List LDAPGroups command displays all defined LDAP group with their access privilege level. To display
Adding serial port access to an LDAP group The Add PortToLDAP command grants an LDAP group access to the serial port. To grant serial port access to
Chapter 2: Installation Before installing your Sentry Commander, refer to the following lists to ensure that you have all the items shipped with the u
LDAP Technical Specifications 60 • Advanced Operations Sentry Commander - PT40 Simple Bind Authentication ProcessLDAP Server SentryClien
TACACS+ The Sentry family of products supports the Terminal Access Controller Access Control System (TACACS+) protocol. This enables authentication
Setting the TACACS+ encryption key The Set TACACS Key command sets the encryption key used to encrypt all data packets between the Sentry and the TACA
Configuring TACACS+ Privilege Levels Setting TACACS+ account access level privileges The Set TacPriv Access command sets the access level privileges f
Deleting outlet access for a TACACS+ account The Delete OutletFromTACACS command removes a TACACS+ account’s access to one or all outlets. You canno
TACACS+ Technical Specifications Authentication START Packet includes: action = 1 (TAC_PLUS_AUTHEN_LOGIN) priv_lvl = 0 (TAC_PLUS_PRIV_LVL_MIN) authen_
Chapter 5: Appendices Appendix A: Resetting to Factory Defaults You may reset the non-volatile RAM that stores all configurable options. This clears
Appendix C: Technical Specifications Domestic Models Model Voltage Inlet* Outlets Additional Ports PT40-H404-1-02 100-120V, 50/60Hz IEC 60320 C2
Data Connections RS-232 port Commanders are equipped standard with an RJ45 DTE RS-232c serial port. This connector may be used for direct local acces
Pass-Thru Port The Commander be may be equipped with up to eight RJ12 DTE Pass-Thru ports for connection to serial devices. RJ12 crossover cables are
Installing the Power Input Retention Bracket To install the power input retention bracket: 1. Remove the two screws attaching the IEC 60320 C19 inlet
Regulatory Compliance Product Safety Units have been safety tested and certified to the following standards: • USA/Canada UL 60950:2003 and CAN/CS
Appendix D: Warranty, Product Registration and Support Warranty and Limitation of Liability Server Technology, Inc. agrees to repair or replace Produ
Technical Support Server Technology understands that there are often questions when installing and/or using a new product. Free Technical Support is
Solutions for the Data Center Equipment Cabinet Server Technology, Inc. +1.800.835.1515 TF 1040 Sandhill Drive +1.775.284.2000 Tel Reno, NV 8
Connecting to the Unit Serial (RS232) port The Commander is equipped with an RJ45 Serial RS-232 port for attachment to a PC or networked terminal serv
Chapter 3: Operations INTERFACES 10 Outlet Naming and Grouping 10 Usernames and Passwords 10 HTML INTERFACE 11 Logging In 11 Outlet Control 12 Indiv